# Lyophilized peptide vials wholesale

> International Wholesale Peptides sells lyophilized peptide vials wholesale to verified trade buyers in kits of 10 vials. Each lot carries a certificate of analysis reporting identity, HPLC purity and peptide content. Research-grade vials are for laboratory research by verified institutions; not for human or veterinary use.

Source: https://internationalwholesalepeptides.com/formats/lyophilized-vials/
Updated: 2026-11-21

International Wholesale Peptides (IWP) sells lyophilized peptide vials wholesale to verified trade buyers and institutions. Each vial holds a freeze-dried peptide cake under a stoppered, crimped closure, and each lot ships with a certificate of analysis that names the testing laboratory. Research-grade vials are for laboratory research by verified institutions; not for human or veterinary use.

## Lyophilized peptide vials wholesale: specification

| Attribute | Specification |
| --- | --- |
| Container | Type I borosilicate glass tubing vial. Glass color options and vial size are stated on the quote |
| Closure | Elastomeric lyophilization stopper with an aluminum crimp seal and flip-off cap. Cap color options are stated on the quote |
| Fill | Quantity per vial as stated on the label and certificate, identified as gross powder or net peptide |
| Appearance | White to off-white cake or powder, unless the certificate states otherwise |
| Pack | Kit of 10 vials from one lot |
| Label | Bulk unlabeled with the lot on the carton, trade label, or your label. Labels are priced per unit on the quote |
| Storage | Per certificate |
| Shelf life | Per certificate |
| Shipping | Stock-list items leave in 2 to 5 business days. Most product is made to order in about 3 weeks. Shipping condition is stated on the quote |
| Sterile water | A separate catalogue item in 10, 20 and 30 mL vials, quoted on request for destinations where it can be supplied |
| Documents | Certificate of analysis and origin statement for the lot |

Vial size, fill and label options for a specific item are confirmed on the quote. Origin is stated per lot under one of three origin statements.

| Origin statement | Active ingredient | Filled, finished and tested |
| --- | --- | --- |
| USA-Synthesized | Made in the United States | In the United States |
| US-Finished | Made outside the United States, source country disclosed | Filled, freeze-dried, finished and tested in the United States |
| Standard | Made outside the United States | Finished outside the United States |

We publish no preparation volumes and no instructions for any vial or for sterile water.

## Product range

The table lists the compounds and blends supplied or quoted as lyophilized vials. Catalogue strengths are on the category pages of the [research-use-only catalogue](/research-peptides/).

| Group | Items in lyophilized vials |
| --- | --- |
| Single peptides | Adamax, adipotide, AOD-9604, ARA-290, BPC-157, CJC-1295 with DAC, CJC-1295 without DAC, DSIP, epitalon, FOXO4 peptide, GHK-Cu, GHRP-2, GHRP-6, gonadorelin, hexarelin, humanin, IGF-1 LR3, ipamorelin, kisspeptin-10, KPV, LL-37, melanotan-1, melanotan-2, MGF, PEG-MGF, MOTS-c, oxytocin, P-21, PE-22-28, PT-141 (bremelanotide), Selank, Semax, sermorelin, SNAP-8, SS-31, TB-500, TB-500 fragment, tesamorelin, thymosin alpha-1 |
| Short peptide bioregulators | Cardiogen, Cartagen, pinealon, prostamax, testagen, thymalin, vesugen, vilon |
| Other compounds | 5-amino-1MQ, AICAR, L-glutathione, NAD+ |
| Two-peptide blends | CJC-1295 without DAC with ipamorelin; tesamorelin with ipamorelin; BPC-157 with TB-500; BPC-157 with TB-500 fragment; Selank with Semax |
| Three- and four-component blends | GHK-Cu, BPC-157 and TB-500; the same blend with KPV; NAD+, MOTS-c and 5-amino-1MQ |
| GLP research compounds, by catalogue code | GLP-1, GLP-2, GLP-3, cagrilintide, survodutide; cagrilintide with GLP-1; GLP-3 with cagrilintide; GLP-1 with BPC-157; GLP-2 with BPC-157 |

Quantity per vial for each item is stated on the quote. GLP-1, GLP-2 and GLP-3 are catalogue names used as codes, not chemical names; the identity of each lot is stated on its certificate of analysis. Items in the GLP class, and compounds that are actives of approved prescription medicines or investigational compounds, are supplied to verified research institutions only. Their regulatory status is stated on the [compound sheets](/compounds/) and the [GLP Research Compounds](/research-peptides/glp-research-compounds/) page. The single-compound list is on the [Research Peptides](/research-peptides/peptides/) page and the combination vials are on the [Peptide Blends](/research-peptides/peptide-blends/) page.

## How a lyophilized peptide vial is made

The steps below describe the general process for this format. They explain what the specification and the certificate are controlling.

### Compounding and filtration

Purified peptide is dissolved to a target concentration, often with a bulking agent such as mannitol where the fill mass is too small to form a stable cake. The solution passes through a 0.22 micron sterilizing-grade filter into a clean receiving vessel. Filter integrity is checked after use.

### Aseptic filling

Washed, depyrogenated vials are filled by volume under unidirectional airflow. Fill weight is checked at intervals during the run, because the fill volume sets the quantity in every vial. Stoppers are placed in the half-seated position so that vapor can leave through the stopper vents during drying.

### The lyophilization cycle

1. **Freezing.** Shelves are cooled until the solution is fully solid. The freezing rate sets the ice crystal size, which later sets how easily vapor escapes.
2. **Primary drying.** Chamber pressure is lowered and shelf temperature raised so that ice sublimes. The product must stay below its collapse temperature. Above it, the cake loses structure.
3. **Secondary drying.** Shelf temperature is raised further to remove water bound to the solid. This step sets the residual moisture.

Residual moisture is the main stability variable in a finished cake. Too much water allows the degradation reactions that freeze-drying was meant to slow. The [lyophilization guide](/guides/lyophilization-explained/) covers cycle design.

### Stoppering and sealing

At the end of the cycle, the shelves close and press the stoppers fully home, under vacuum or an inert gas backfill. Vials are then crimped. Container closure integrity depends on the fit between vial finish, stopper and crimp. A closure that leaks lets in moisture and loses headspace vacuum, and the cake degrades without a visible cause.

## What the certificate reports for a vial lot

| Test | Method | Reported |
| --- | --- | --- |
| Identity | Mass spectrometry | Every lot |
| Purity | Reversed-phase HPLC | Every lot |
| Peptide content | Method named on the certificate | Every lot |
| Bacterial endotoxin | LAL, USP <85> | Where relevant |
| Sterility | USP <71> | Where relevant |

Purity and peptide content are different measurements. Purity describes the peptide-related material. Peptide content is the share of the solid that is peptide once counter-ion and water are counted. The counter-ion, usually acetate or trifluoroacetate, is stated on the certificate. Our [quality page](/quality/) explains each test, and any lot number can be checked through [lot lookup](/quality/lot-lookup/).

## Receiving, storage and handling

Inspect each case on arrival. Check that kit and vial lot numbers match the packing list. Look at the cake and the crimp before the kits go into storage.

Store to the condition on the certificate. Shelf life is stated per certificate and applies to unopened vials held in that condition. Record storage temperatures, since an unrecorded excursion cannot be assessed later. Keep vials in their kit cartons to protect them from light and to keep the lot together.

### Cold chain, explained plainly

Cold chain means the product stays within its labeled temperature range from the filling line to your shelf. It is a record as much as a box: the range is printed on the label, and the buyer should be able to show the product stayed inside it.

| Stage | What keeps the vial in range | What the buyer checks |
| --- | --- | --- |
| At the filling site | Storage at the labeled condition after sealing | The storage statement on the certificate |
| In transit | The shipping condition stated on the quote. Temperature-controlled packing, where an item needs it, is a separate line on the quote | Carton condition, and the logger record where one is included |
| On your shelf | Your storage at the labeled condition, with a temperature record | That the vials went into storage on the day of delivery |

A freeze-dried cake holds very little water, so it tolerates transit better than a solution vial or a cartridge. That is why the shipping condition for a freeze-dried item can differ from its storage condition. Neither is assumed. Both are stated for the item. Transit damage is reported within 48 hours of delivery, with photographs.

The [storage and cold chain guide](/guides/peptide-storage-and-cold-chain/) covers receiving checks and excursion handling for distributors and laboratories.

## Who can order this format

Lyophilized vials are sold to verified research institutions, CROs and biotech companies, and to distributors and brands that supply them. The pages for [research institutions](/for/research-institutions/) and [distributors and importers](/distributors/) set out the route for each. Pharmacies are quoted bulk API powder, not research-grade vials.

Ordering follows the same path for every buyer: apply, business verification, quote, order. A first order of made-to-order product starts from US$10,000, prepaid by bank wire or ACH. Stock-list vials can be bought once per account as an evaluation order from US$2,500, so a buyer can test a lot before a production order. Private-label vials typically start at 50 kits (500 vials) per item, stated on the quote, and a first private-label order takes 4 to 6 weeks from approved artwork. To request a quote, [apply for an account](/apply/).

## Frequently asked questions

### What is a kit?

One kit is 10 vials of one item from one lot. Volume price breaks apply at 50, 150, 300 and 500 kits per item, which is 500, 1,500, 3,000 and 5,000 vials, and a reached level is kept on later orders of that item. Kits are packed in shipping cases, and the lot number appears on every vial label, on the kit and on the packing list.

### Why are peptides supplied lyophilized instead of in solution?

Most peptides degrade faster in water, through hydrolysis, deamidation and oxidation. Freeze-drying removes water at low temperature, which slows those reactions and gives a solid that stores and ships more predictably. The storage condition and shelf life for each lot are stated on its certificate.

### Does the amount on the label mean net peptide?

The certificate states whether the labeled quantity is gross powder or net peptide. Gross powder includes counter-ion and residual water. Use the peptide content result on the certificate to convert between the two, and record the lot number with any calculation.

### What does a collapsed cake mean?

A cake that has shrunk, melted or pulled away into a film was exposed to moisture or heat, or was dried above its collapse temperature. It can also indicate a leaking closure. Report it with the lot number and a photograph before opening the vial.

### Do you supply sterile water or diluent with vials?

Sterile water in 10, 20 and 30 mL vials is a separate catalogue item, quoted on request for destinations where it can be supplied. It is not packed with peptide vials by default. We publish no preparation volumes and no instructions, and research-grade vials are not for human or veterinary use.

### What does cold chain mean for freeze-dried vials?

Cold chain means the product stays within its labeled temperature range from the filling line to your shelf. A freeze-dried cake tolerates transit better than a solution, so the shipping condition can differ from the storage condition. Both are stated for each item, on the quote and on the certificate.

### Are the vials sterile?

Sterility is reported on the certificate where it is relevant to the product and was tested for that lot, by USP <71>. If the certificate has no sterility line, the lot should not be assumed sterile. Research-grade vials are not for human or veterinary use in any case.